Method

Roche Cobas e411. Electrochemiluminescence.

Diagnostic Use / Indications

Assessment of ovarian response in infertile women treated with gonadotrophins or gonadotrophin-releasing hormone. (Results should be interpreted in association with ultrasound findings.)

Assessment of ovarian function.

Investigation of patients with estrogen producing tumours.

External Price$17.10(Exclusive of GST)
  

Specimen Collection

 
Pre-Testing Requirements

Preferred sampling between 0800 and 1000 hours.

Specimen Collection Protocols

None

Patient SpecimenBlood 2 mL; serum(Red), Heparin(Green), EDTA(Lav)
Paediatric Specimen1 mL
Sample Delivery to LabAmbient
  

Instructions for Referral to CHLabs

 
Aliquot Instructions1 mL serum or plasma. Minimum 0.5 mL.
Aliquot Transport to CHLAmbient.
  

CHLabs Laboratory

 
DepartmentEndocrinology Laboratory
Contact Details Email Email
This e-mail address is being protected from spam bots, you need JavaScript enabled to view it
Contact Phone Number(03) 364 0885 | x80885
Test AvailabilityDaily weekdays.
Turnaround Time1 - 4 days
Reference Interval

Female:
Pre-menopausal: follicular 100-570, luteal 120-1100 pmol/L
Post-menopausal: <180 pmol/L
Ranges exclude OC and HRT. OC tends to lower estradiol levels.

Male: <190 pmol/L.

Interpretation
  1. Serial results should be interpreted only on a single assay.
  2. Measurement uncertainty is approximately 10% for levels >180 pmol/L and ±20 pmol/L for levels <180 pmol/L.
  3. Detection limit of this Roche assay is 18.4 pmol/L
  4. Refer to the laboratory in the event of any clinical discordance or uncertainty.
Uncertainty of Measurement

+/- 18.4 pmol/L for < 99 pmol/L

+/- 18.6% for > 99 pmol/L

Delphic Number Test Number5795